DJ-SB Plateframe Scales
The DJ-SB is an extension of our PSB, which has been proven for 10 years. Platform and measurement technology are identical, the difference is only in the display.
Instead of the sensitive LCD, we have installed an LED display panel.
Our experience of recent years has shown that the display wall mount, included with each balance, is often not used and the display is loose on the table. If now something falls on the display or the display itself drops down, the sensitive LCD panel can be damaged (the liquid crystals in the display run out leaving a black spot, the weight can not be read).
The DJ-SB uses an insensitive LED display instead of the LCD, which is more resistant to shocks and falls.
Another advantage is the resistance to cold:
In recent years, more and more online shops specialize in the supply of chilled or frozen food, in which the goods in the cold store at -20 ° C is packed. Other customers rely on the scale to work outdoors in winter as well.
Liquid crystals in conventional LCD displays can freeze at these temperatures, usually no permanent damage but the scale is not functioning until it "thaws". A LED has no susceptibility to frost, which lights up at any temperature.
(Note: The balance is calibrated before shipment at room temperature and works best in the measuring range of 5 ° C - 35 ° C. If the balance is used below 5 ° C, we recommend a new calibration under these conditions to avoid temperature-related measurement errors Also, please note that normal alkaline batteries do not work when it is freezing. You can use the balance either with the AC adapter or with special frost-resistant lithium batteries).
Scale |
DJSB-75 |
DJSB-150 |
DJSB-300 |
DJSB-300B |
Weighing Range |
75 Kg |
150 Kg |
300 Kg |
75 Kg | 150 Kg | 300 Kg |
Readout (1 readout step = 1d) |
10 g < 5 Kg > 20 g |
20 g < 10 Kg > 50 g |
50 g < 20 Kg > 100 g |
20 g < 75 | 50 g < 150 Kg | 100 g < 300 Kg |
Tara Range |
75 Kg |
150 Kg |
300 Kg |
300 Kg |
Linearity |
± 5 * d |
± 5 * d |
± 5 * d |
± 5 * d |
Reproducibility |
± 2 * d |
± 2 * d |
± 2 * d |
± 2 * d |
Minimum weight*: |
100g |
200g |
500g |
200g |
Settling time: |
< 4 s |
< 4 s |
< 4 s |
< 4 s |
Warm-up time ** |
10 Minutes |
10 Minutes |
10 Minutes |
10 Minutes |
Calibration weight *** |
50kg |
100kg |
200kg |
200kg |